JavaScript is required to use the Windy City Wire site

Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables

About this category

Summary: Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables

Security & Access Control Shielded Indoor/Outdoor Water Warrior® SmartWire Cables

Windy City Wire manufactures SmartWire low-voltage cable in the United States for professional security and access control projects. Our Shielded Indoor/Outdoor Water Warrior® cables are built for dependable operation in wet or dry locations, helping integrators deliver stable reader, lock, and panel performance across demanding facilities. With overall foil shielding to limit EMI/RFI and bare copper conductors for solid terminations, these cables support clean signal integrity, predictable voltage drop, and code-conscious installation methods for modern security systems.

Why choose Windy City Wire for your next access control cable run

  • Indoor/outdoor, wet-location ready: Water Warrior® construction supports use in wet areas while maintaining the flexibility and durability installers expect in the field.
  • Shielded for noise control: An overall aluminum foil shield helps reduce interference near elevators, VFDs, generators, and HVAC equipment—ideal for card readers, REX devices, door contacts, and control I/O.
  • UL application coverage: Available with UL Types TC, PLTC, FPL, or NPLF for tray and power-limited/fire alarm circuits in non-plenum spaces; a practical fit for many security and access control pathways.
  • SmartWire Glide Technology®: Factory-applied lubrication reduces friction during pulls by up to 70%, helping installers work efficiently through conduit and long pathways.
  • Bare copper conductors: Reliable connectivity, easier terminations, and consistent resistance characteristics for 12/24V access control power and signaling.
  • Right-size options: 16 and 18 AWG selections with 2–8 conductors align with common door hardware, reader power, and supervisory circuits.
  • Color-coded conductors: Streamlined device identification and quicker terminations during installation and service.

Typical applications

  • Card readers, keypads, and door contacts
  • Request-to-exit (REX) sensors and motion detection at openings
  • Electric strikes, maglocks, and door hardware requiring 12/24V power
  • Control panel I/O, relays, and power supply connections
  • Security and fire alarm signaling in non-plenum spaces where shielding is beneficial

At-a-glance options

  • Available AWGs: 16, 18
  • Conductor counts: 2, 4, 6, 8 (model dependent)
  • Shielding: Overall aluminum foil (O/A foil)
  • Lengths: 1000 FT, 500 FT
  • Conductor color codes: Black/Red; Black/Red/Blue/Orange; Black/Red/Orange/Blue; Black/Red/Blue/Orange/Yellow/Brown; Black/Red/Blue/Orange/Yellow/Brown/Pink/Purple

How this product line adds value

  • Consistency across jobs: US-made SmartWire helps standardize your specification and installation practices across sites and teams.
  • Fewer callbacks: Shielded performance and bare copper conductors support stable device operation and cleaner signals, cutting down on troubleshooting time.
  • Project fit: Multiple gauges, conductor counts, and UL Types make it straightforward to match cable choice to lock power, control signaling, and pathway requirements.

Available constructions

  1. 16 AWG 2 Conductor Bare Copper Non-Plenum UL Type TC/PLTC/FPL/NPLF: Shielded (O/A foil) pair for higher-current door hardware or longer power runs in indoor/outdoor and wet locations. A practical choice for maglocks and strikes where voltage drop is a concern.
  2. 16 AWG 4 Conductor Bare Copper Non-Plenum UL Type TC/PLTC/FPL/NPLF: Shielded 4-conductor cable that lets you combine lock power with control or monitoring circuits in a single pull. Suitable for noisy environments where EMI mitigation is important.
  3. 18 AWG 2 Conductor Bare Copper Non-Plenum UL Type TC/PLTC/FPL/NPLF: Shielded pair for standard access control power or signaling over moderate distances. Well suited for card readers and auxiliary devices.
  4. 18 AWG 4 Conductor Bare Copper Non-Plenum UL Type TC/PLTC/FPL/NPLF: Shielded 4-conductor construction that supports reader power plus data or mixed device wiring. A common go-to for door openings that need both power and control.
  5. 18 AWG 6 Conductor Bare Copper Non-Plenum UL Type TC/PLTC/FPL/NPLF: Shielded 6-conductor option for doors with additional I/O, monitoring, or auxiliary relays. Helps consolidate multiple circuits to a single pathway.
  6. 18 AWG 8 Conductor Bare Copper Non-Plenum UL Type TC/PLTC/FPL/NPLF: Shielded 8-conductor cable for complex openings or multi-function devices where extra conductors reduce additional pulls. Effective in areas with potential electrical noise.

Note: All products in this category are low-voltage, shielded, and suitable for indoor/outdoor use in wet locations. For plenum spaces or other specialized requirements, contact Windy City Wire to discuss additional SmartWire options.

Solutions: Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables

Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables are engineered for dependable low-voltage performance in demanding environments. Built for indoor/outdoor use and suitable for wet locations, these shielded, non-plenum constructions help protect critical security signals from moisture and electrical noise so doors open when they should, alarms trigger when required, and audits remain accurate. With UL listings that include TC, PLTC, FPL, and NPLF, they support a broad range of power-limited and control applications across modern enterprise facilities.

Where these cables excel

  • Access control cabling for card readers (Wiegand/OSDP), keypads, door position switches (DPS), request-to-exit (REX) sensors, door strikes, and maglocks
  • Perimeter and gate control for vehicle gates, turnstiles, barrier arms, bollards, and fence detection systems
  • Video and intercom support for door stations, emergency call boxes, help points, and ancillary power/control for cameras or housings
  • Intrusion detection including glass break, motion, beam sensors, and relay interfaces
  • Elevator and life-safety interfaces such as access panel-to-elevator controller signaling and supervised connections to fire alarm control panels (where permitted by listing and code)
  • BMS/BAS and RS‑485 control for controllers, relays, and modules that benefit from shielded, low-voltage control runs

Industries and environments

  • Commercial offices and multi-tenant buildings
  • Healthcare campuses, clinics, and laboratories
  • Education (K‑12 and higher education) and large campuses
  • Industrial plants, utilities, water/wastewater facilities, and warehouses
  • Transportation hubs, parking structures, and logistics yards
  • Data centers and critical infrastructure
  • Hospitality, retail, and mixed-use properties
  • Municipal, public safety, and government facilities

Why a shielded, wet-location cable matters

  • Moisture resistance for indoor/outdoor runs: Designed for wet locations, the Water Warrior® construction helps resist water ingress commonly found in outdoor enclosures, parking decks, or underground conduits.
  • Noise immunity for sensitive signals: An overall foil shield (O/A) helps reduce EMI/RFI on Wiegand, OSDP, and RS‑485 communications, improving system reliability and reducing nuisance troubleshooting.
  • Broad UL applicability: TC and PLTC listings support tray and power-limited control circuits; FPL/NPLF listings support fire alarm-related interfaces where permitted by local code. Always confirm with the Authority Having Jurisdiction (AHJ).
  • Non-plenum efficiency: Ideal for general-purpose and riser pathways where plenum rating is not required.

Construction options to match the application

  • Available AWGs: 16 AWG and 18 AWG to balance voltage drop and device current needs over longer runs
  • Conductor counts: 2, 4, 6, and 8-conductor options (application-driven for readers, sensors, and combined power/control)
  • Bare copper conductors: Consistent, low-resistance performance for power-limited and control circuits
  • Shielded design: Overall aluminum foil shield for consistent signal integrity
  • Jacket color: Black jacket suitable for a wide range of facility aesthetics and outdoor visibility needs
  • Conductor color coding: Clear, industry-friendly color sets (for example: Black/Red for 2C; expanded color sets on higher conductor counts) to speed terminations and service
  • Lengths: Available in 1000 FT and 500 FT to accommodate large projects and smaller add-ons or change orders

Common system integrations

  • Access platforms: Controller-to-reader, reader-to-door hardware, and panel I/O for lockdowns, anti-passback, and audit trails
  • Video management systems (VMS): Auxiliary power/control for field devices, housings, and relays
  • Intrusion and duress: Sensor loops, panic buttons, and supervised circuits
  • Fire/life-safety coordination: Door release, elevator recall, and emergency egress interface wiring where listings and codes permit
  • Parking and revenue control: Gate operators, loop detectors, ticketing and validation equipment

Selecting the right cable for the job

  1. Match AWG to distance and load: Use 16 AWG where current draw is higher or runs are longer (e.g., maglocks, strikes); 18 AWG is common for readers, keypads, and sensors.
  2. Choose conductor count by device set: 2C is typical for basic power or contacts; 4C supports many readers and combined power/signal; 6C/8C supports multi-function doors or combined device runs.
  3. Use shielded cable for data-bearing lines: Especially for Wiegand, OSDP, RS‑485, or where cabling runs in parallel with power or near motors and VFDs.
  4. Confirm pathway and listing needs: TC/PLTC for tray or control circuits; FPL/NPLF for permitted fire alarm interfaces. Verify with project specifications and the AHJ.
  5. Plan for environment: For outdoor enclosures, garages, and damp or flooded conduits, select the Water Warrior® shielded construction rated for wet locations.

Typical device-to-cable mapping examples

  • Card reader (Wiegand/OSDP): 18/4 or 18/6 shielded
  • Door strike or maglock: 16/2 or 18/2 depending on run length and current
  • DPS + REX + strike on one opening: 18/6 or 18/8 shielded, or separate 18/4 (reader) plus 16/2 (lock)
  • Gate operator controls: 18/4 or 18/6 shielded for command and status, 16/2 for power-limited loads

Windy City Wire’s shielded, indoor/outdoor Water Warrior® low-voltage security cable gives integrators, contractors, and facility teams a dependable foundation for access control and related systems. With multiple AWGs, conductor counts, shielded construction, and lengths available, these cables help simplify design, reduce callbacks, and support consistent system performance across complex, multi-building sites.

Frequently Asked Questions: Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables

  • What AWG conductors are available with this SmartWire Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables cable?

    16 AWG and 18 AWG.

  • What other colors is this SmartWire Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables cable available in?

    Available conductor color codes:
    - Black/Red
    - Black/Red/Blue/Orange
    - Black/Red/Orange/Blue
    - Black/Red/Blue/Orange/Yellow/Brown
    - Black/Red/Blue/Orange/Yellow/Brown/Pink/Purple

  • Is this SmartWire Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables cable made with solid or stranded copper conductors?

    Stranded bare copper conductors for flexibility and reliable terminations in security and access control installations.

  • What length is this SmartWire Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables cable sold in?

    Windy City Wire manufactures and stocks SmartWire Security & Access Control cable in a 1,000 ft standard length. This series is also available in 500 ft lengths.

  • What are some distinctions between BAC NET, RS232 and RS485 Cables?

    BACnet (MS/TP) typically runs over RS485 cabling: a shielded, twisted pair (120 Ω) for differential signaling, supporting multidrop networks and long runs in noisy environments.
    RS232 is single-ended and point-to-point, short distance, and often uses a shielded multi-conductor cable (e.g., TX, RX, GND); it is more susceptible to noise and not intended for long runs.
    RS485 is differential, supports multidrop (bus) topologies, long distances (up to thousands of feet at lower data rates), and relies on shielded twisted pair with proper termination and biasing. In short: BACnet MS/TP commonly uses RS485-type cable; RS232 requires fewer conductors and is for short, point-to-point links; RS485 uses twisted, shielded pairs for longer, noise-immune networks.

Summary: Security & Access Control Shielded Outdoor INDOOR/Outdoor Water Warrior® | SHIELDED Cables

Security & Access Control Shielded Indoor/Outdoor Water Warrior® SmartWire Cables

Windy City Wire manufactures SmartWire low-voltage cable in the United States for professional security and access control projects. Our Shielded Indoor/Outdoor Water Warrior® cables are built for dependable operation in wet or dry locations, helping integrators deliver stable reader, lock, and panel performance across demanding facilities. With overall foil shielding to limit EMI/RFI and bare copper conductors for solid terminations, these cables support clean signal integrity, predictable voltage drop, and code-conscious installation methods for modern security systems.

Tip: Use the product search in our header to find additional products not featured in this catalog
Updating products…